Português
Components

Aiming at meeting the aesthetical demands of your patients, Dentoflex invests in prosthetic solutions making them even more agile and reliable day after day.

The variety of components that the company produces intends to cover the majority of cases you have when in surgery, thus exceeding your patients’ most difficult expectations.

Prothetics Components:

  1. Esteticone analogue

• Used in the work model to produce dental prosthesis
• Stainless steel



 

Instructions of Use


  2. Analogue for wax one

• Used in the work model for dental prosthesis production
• Stainless steel





 

Instructions of Use

  3. Clips bar

• Recommended for overdenture
• It includes 3 clips (straight; 35º; 70 º) and two bars






 

Instructions of Use



  4. Handle of prosthetic component

• Used to hold the prosthetic component when necessary to abrade


 

Instructions of Use


  5. Healing cover

• Promotes gingival tissue healing and protects the esteticone base
• Titanium


 

Instructions of Use

  6. Wax one

• Titanium
• Titanium fixation square screw and plastic exhaust device included
• Brace height: 1; 2; 3; 4 and 5mm
• 32N torque

Instructions of Use



  7. Healer with emergency profile – spe

• Promotes guided healing of the gingival tissue
• Provides more aesthetical restorations
• Titanium
• Available in width profiles (E) of 5,0; 6,0 and 7,5mm

Instructions of Use


  8. Parallel healer flex

• Promotes guided healing of the gingival tissue
• Titanium
• Diameter: 5,00mm




 

Instructions of Use

 

  9. Straight Healer

• Promotes guided healing of the gingival tissue
• Titanium


Instructions of Use


10. Esteticone sleeve

• Anti-rotational exhaust device recommended for screwed unitary prosthesis
• Circular exhaust device recommended for screwed fixed prosthesis
• Available in plastic and metal




 


Instructions of Use

11. Plastic exhaust device for wax one

• Perfect adaptation
• Accepts casting in noble metal or not




Instructions of Use

12. Angulate steticone

• Used for screwed prosthesis – unitary or fixed
• It includes titanium fixation central screw and micro screw for prosthesis
• Titanium
• Brace height: 1; 2 and 3mm
• Available with 17º; 22º and 30º inclinations
• Central screw torque: 20N; micro screw torque: 10N

Instructions of Use


13. Straight esteticone

• Used for screwed prosthesis – unitary or fixed
• Includes titanium fixation central screw and micro screw for prosthesis
• Titanium
• Brace height: 1; 2; 3; 4 e 5mm
• Central screw torque: 20N; micro screw torque: 10N

Instructions of Use

 

14. Transmucose modifier HI

• Used to transform the seating base of the internal hexagon implant (HI) in external hexagon (HE)
• Titanium fixation square screw included
• Titanium
• Brace height: 1; 2; 3; 4 and 5mm
• Torque: 30N


 

Instructions of Use


15. Angulate trunnion

• Used as base in the production of permanent, cemented, unitary or fixed prosthesis,
aiming to correct inclination of implants
• Titanium
• Brace height: 1; 2; and 3mm
• Titanium fixation square screw included
• Available with inclination of 15º; 25º and 35º
• Torque: 32N

Instructions of Use


16. Angulate trunnion – hexagon position

To cover the various inclinations of the implant to favour aesthetics. The implantodontist
can choose:

• Position 01 (P1): When the Hexagon face is directed to the vestibular
• Position 02 (P2): When the hexagon vertex is directed to the vestibular

 


Instructions of Use


17. Anti-rotational trunnion for fixed

• Recommended as base in the production of cemented fixed prosthesis
• It includes titanium fixation screw with square groove
• Titanium
• Brace height: 1; 2; 3; 4 and 5mm
• 32N torque

Instructions of Use


18. Anti-rotational trunnion for unitary

• Used as base in the production of cemented unitary prosthesis
• Titanium fixation square screw included
• Titanium
• Brace height: 1; 2; 3; 4 and 5mm
• Torque: 32N

 

Instructions of Use



19. Trunnion with shoulder

• Used as base in the production of cemented fixed prosthesis, provisory or permanent
• Titanium
• Brace height: 1; 2; 3; 4 e 5mm

 

Instructions of Use


20. Trunnion for preparation

• Recommended as base in the production of cemented fixed prosthesis, permanent
or temporary
• Titanium
• Brace height: 1; 2; 3mm
• 32N torque

Instructions of Use


21. Standard trunnion

• Used as base in the production of cemented fixed prosthesis, permanent or temporary
• Titanium
• 30N torque

Instructions of Use


22. Temporary trunnion for cemented prosthesis

• Used as base in the production of temporary prosthesis
• Titanium fixation square screw included
• Surgical stainless steel
• Standard brace height of 1mm
• Available for anti-rotational and circular
• 30N torque

Instructions of Use


23. Temporary trunnion for screwed prosthesis

• Used as base in the production of temporary prosthesis
• Titanium fixation square screw included
• Surgical stainless steel
• Standard brace height of 1mm
• Available for anti-rotational and circular
• 30N torque

Instructions of Use

 

24. O ’ring

• Used in overdenture retention
• Titanium
• It includes plastic capsule for transferrence, titanium capsule and spacer ring
• Brace height: 1; 2; 3; 4 and 5mm

Instructions of Use


25. Fusible o-ring

• Used in overdenture retention
• Intra-radicular use
• It includes plastic capsule for transferrence, titanium capsule and spacer ring

 

 

Instructions of Use


26. Esteticone transfer

• Used for transferring the esteticone position to work model
• Stainless steel
• Available in anti-rotational and circular and with SPE profile






Instructions of Use

 

27. Open moulder transfer – Square transfer

• Recommended for transferring the implant position to the work model
• Used for open individual moulder
• Stainless Steel
• Available in: short, medium and long sizes

Instructions of Use


28. Open moulder transfer with emergency profile – spe

• Recommended for transferring the implant position to the work model
• Used in moldings where the healer with emergency profile is used
• Used for open individual moulder
• Stainless steel
• Available in width profiles of 5,0; 6,0 and 7,5mm

Instructions of Use

 

29. Closed moulder transfer

• Recommended for transferring the implant position to the work model
• Used with stock moulder
• Stainless steel

Instructions of Use


30. Wax one transfer

• Used to transfer the Wax one position to work model
• Stainless steel





 

Instructions of Use


31. Plastic transfer for trunnion with shoulder CM

• Used for making the trunnion with shoulder transferrence
• Plastic

 

 

 

Instructions of Use


32. Ucla with metallic brace

• Used in the production of permanent prosthesis
• Titanium fixation square screw and work screw (laboratorial) included
• Machine-made base in surgical stainless steel which enables better prosthesis adaptation
• Over casting in noble or non-noble metal (except Tillite)
• Standard brace height of 1mm
• Available for anti-rotational and circular
• 32N torque

Instructions of Use



33. Plastic ucla

• Used in the production of permanent prosthesis aiming to personalize the prosthesis anatomy
• Titanium fixation square screw and work screw (laboratorial) included
• Standard brace height of 1mm
• Available for anti-rotational and circular
• 32N torque

Instructions of Use

 

Flex Implant:

1. Analogue Flex

• Used in the work model to produce dental prosthesis
• Stainless steel







 

Instructions of Use



2. Healer with emergency profile – spe flex

• Promotes guided healing of the gingival tissue
• Provides more aesthetical restorations
• Titanium
• Available in width profiles (E) of 5,0; 6,0 and 7,5mm





 

Instructions of Use



3. Parallel healer flex

• Promotes guided healing of the gingival tissue
• Titanium
• Diameter: 5,00mm




Instructions of Use


4. Plastic sleeve flex

• Perfect adaptation
• Accepts casting in noble and non-noble metal




Instructions of Use


5. Metallic sleeve flex

• Used as base in the production of fixed prosthesis
• Fixation screw included
• In titanium





 

Instructions of Use



6. Plastic sleeve flex

• Circular sleeve recommended for screwed fixed prosthesis
• Anti-rotational sleeve recommended for screwed unitary prosthesis
• fixation screw included




 

 

Instructions of Use



7. Transfer with spe flex profile

• Used to transfer the esteticone position to the work model
• Stainless steel
• Available in anti-rotational and circular and with SPE profile






 

Instructions of Use


8. Transfer flex

• Used to transfer the esteticone position to the work model
• Stainless steel
• Available in anti-rotational and circular








Instructions of Use




Dentoflex © 2008 | Desenvolvido por Studio Knove.com